T2505

Coils and Transformers

REACTOR

T2505

5950-01-227-1030

5950 - Coils and Transformers

Magnetika Inc

REACTOR

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Rating Method

    electrical single component single winding and winding turns single component single winding

  • Frequency Rating

    10.0 kilohertz nominal single component

  • Body Length

    0.500 inches maximum

  • Winding Conductor Size

    0.02257 inches american wire gage single component single winding

  • Inclosure Type

    fully inclosed

  • Winding Operating Current

    2.5 amperes dc maximum single component single winding

  • Dc Resistance Rating In Ohms

    0.050 single component single winding

  • Inductance Rating

    35.00 microhenries minimum single component single winding

  • Winding Quantity

    1 single component

  • Terminal Type And Quantity

    2 wire lead

  • Turn Quantity

    32 single component single winding

  • Maximum Operating Temp

    85.0 deg celsius

  • Reliability Indicator

    not established

  • Mounting Method

    terminal single group

  • Body Outside Diameter

    0.760 inches maximum

  • Inductance Type

    fixed

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.