MS25244-30

Circuit Breakers

CIRCUIT BREAKER

MS25244-30

5925-01-227-4047

5925 - Circuit Breakers

Military Standards

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Ultimate Trip Time Per Pole In Seconds

    138.000 nominal single location

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    200.0 single location

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.796 inches minimum and 1.828 inches maximum

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location

  • Specification/Standard Data

    96906-ms25244 government standard

  • Body Length

    2.189 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Body Width

    0.750 inches maximum

  • Bushing Length

    0.235 inches minimum and 0.265 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location

  • Case Material

    plastic

  • ~1

    data on certain environmental and performance

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches maximum

  • Terminal Type And Quantity

    2 tab, solder lug

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...