MIL-DTL-27715
Circuit Breakers
CIRCUIT BREAKER
MIL-DTL-27715
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performanc
-
Manual Actuator Type And Quantity
1 push-pull
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.800 inches minimum and 1.820 inches maximum
-
Pole Quantity
1
-
Case Material
metal
-
Body Length
2.189 inches maximum
-
Nominal Thread Size
0.138 inches
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location and 28.0 dc single location
-
Center To Center Distance Between Terminals Parallel To Length
1.190 inches nominal
-
Trip Release Characteristic
time delay single location
-
Bushing Length
0.187 inches minimum and 0.249 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Terminal Type And Quantity
2 tab w/screw
-
Inclosure Protection Type For Which Designed
hermetically sealed and sand resistant and salt spray proof and humidity resistant and corrosion resistant and explosion proof and dustproof and vibrationproof and shock resistant and fungus resistant
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location and 5000.0 dc single location
-
Test Data Document
84913-mil-c-27715 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Special Handling Feature
magnetic
-
Thread Series Designator
unc
-
Special Features
circuit breaker must meet vibration test for jet powered aircraft
-
Reset Method
manual
-
Internal Trip Release Configuration
relay trip single location
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Trip Delay Time In Seconds Per Rated Continuous Current
12.000 minimum at 200 pct single location and 32.000 maximum at 200 pct single location
-
Actuator Function
trip-reset
-
Body Width
0.760 inches maximum
-
Mounting Surface To Terminal End Distance
2.370 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Specification/Standard Data
96906-ms24571 government standard
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac single location and 2.5 amperes dc single location
-
Unpackaged Unit Weight
0.200 pounds