NH455-0652-001

Relays and Solenoids

RELAY,ELECTROMAGNETIC

NH455-0652-001

5945-01-227-6441

5945 - Relays and Solenoids

Dla Land And Maritime

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nonpile-Up Main Contact Arrangement

    1 pole, single throw, normally open, momentary action and 3 pole, double throw, one position momentary

  • Coil Quantity

    1

  • Operating Voltage Rating And Type At Specified Temp

    230.0 volts ac 25 deg celsius single winding

  • Test Data Document

    94756-455-0652 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Main Contact Load Current Rating At Maximum Rated Voltage

    2.0 amperes ac motor load and 2.0 amperes dc motor load

  • Duty Type

    continuous

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    0.625 inches nominal single mounting facility

  • Overall Width

    1.025 inches maximum

  • Cubic Measure

    3.170 cubic inches

  • End Item Identification

    b-1b

  • Main Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac inductive load and 4.0 amperes dc inductive load

  • Time Delay

    0.024 seconds maximum fixed operate time

  • Mounting Facility Pattern

    triangle single mounting facility

  • Main Contact Maximum Voltage Rating In Volts

    230.0 ac and 28.0 dc

  • Main Contact Load Current Rating At Maximum Rated Voltage

    2.0 amperes ac lamp load and 2.0 amperes dc lamp load

  • Frequency In Hertz

    400.0 nominal

  • Case Material

    metal

  • Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle

    1.396 inches minimum single mounting facility and 1.446 inches maximum single mounting facility

  • Mounting Facility Type And Quantity

    3 slotted hole single mounting facility

  • Special Features

    nuclear hardness critical item

  • Overall Height

    1.800 inches maximum

  • Overall Length

    1.718 inches maximum

  • Winding Quantity

    1

  • Arc Quenching Method

    air

  • Mounting Slot Width

    0.150 inches nominal single mounting facility

  • Environmental Protection

    hermetic

  • Purpose For Which Designed

    specific

  • Time Delay

    0.0475 seconds maximum fixed release time

  • Main Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac resistive load and 5.0 amperes dc resistive load

  • Criticality Code Justification

    feat

  • Storage Type

    general purpose warehouse

  • Terminal Type And Quantity

    16 pin all functions

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...