MIL-R-6106/41
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MIL-R-6106/41
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performance
-
Overall Height
2.087 inches maximum
-
Overall Length
1.531 inches maximum
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Time Delay
0.01 seconds maximum fixed release time
-
Thread Direction
right-hand single mounting facility
-
Case Material
metal
-
Thread Class
2a single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
25.0 amperes ac resistive load and 25.0 amperes dc resistive load
-
Terminal Type And Quantity
9 wire hook contacts
-
Winding Quantity
1
-
Thread Quantity Per Inch
32 single mounting facility
-
Arc Quenching Method
air
-
Nonpile-Up Auxiliary Contact Arrangement
1 pole, double throw, one position momentary
-
Mounting Facility Type And Quantity
4 threaded stud single mounting facility
-
Environmental Protection
hermetic
-
Storage Type
general purpose warehouse
-
Terminal Type And Quantity
2 pin energizing element
-
Mounting Facility Pattern
rectangular single mounting facility
-
Overall Width
1.531 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.187 inches nominal single mounting facility
-
Nominal Thread Size
0.138 inches single mounting facility
-
Fragility Factor
moderately rugged
-
Time Delay
0.02 seconds maximum fixed operate time
-
Duty Type
continuous
-
Specification/Standard Data
81349-mil-r-6106/41 government specification
-
Thread Series Designator
unc single mounting facility
-
Cubic Measure
4.892 cubic inches
-
Coil Quantity
1
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
Purpose For Which Designed
general
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.187 inches nominal single mounting facility
-
Nonpile-Up Main Contact Arrangement
3 pole, single throw, normally open, momentary action