3179574-20

Circuit Breakers

CIRCUIT BREAKER

3179574-20

5925-01-233-9297

5925 - Circuit Breakers

Navair And Navsea Managed

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nonturn Device Radius

    0.625 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Width

    1.937 inches maximum

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Body Length

    1.562 inches maximum

  • Inclosure Protection Type For Which Designed

    moisture resistant and shock resistant and fungus resistant and vibration resistant and salt spray proof

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Switch Terminal Type

    pin

  • Nonturn Device Diameter

    0.180 inches minimum and 0.300 inches maximum

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Center To Center Distance Between Terminals Parallel To Width

    0.687 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct all locations and 6.000 maximum at 200 pct all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Bushing Length

    0.280 inches minimum and 0.380 inches maximum

  • Test Data Document

    10001-3179574 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Pole Quantity

    2

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Switch Location And Position Designation

    internal at pole two

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Nonturn Device Location

    at 12 oclock

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Mounting Surface To Terminal End Distance

    1.928 inches maximum

  • Terminal Type And Quantity

    4 wire hook

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-single actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...