ETN1046

Circuit Breakers

CIRCUIT BREAKER

ETN1046

5925-01-234-6911

5925 - Circuit Breakers

Spd Electrical Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.625 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.938 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.125 inches nominal

  • Boss Height

    0.125 inches nominal

  • Terminal Type And Quantity

    6 quick disconnect, male

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Frequency In Hertz

    400.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    2.625 inches nominal

  • Body Height

    3.375 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.216 inches nominal

  • Body Length

    4.125 inches nominal

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations and 2500.0 dc all locations

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Test Data Document

    81349-mil-c-17361 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 200.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Specification/Standard Data

    81349-mil-c-17361 government specification

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac all locations and 35.0 amperes dc all locations

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Actuator Position Designation

    at pole two

  • Special Features

    circuit breaker supplied with two 12-24 mounting screws 4.125 in. lg

  • Trip Release Method

    thermal-magnetic all locations

  • Arc Quenching Method

    air

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Body Width

    3.344 inches nominal

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations and 250.0 dc all locations

  • Reset Method

    manual

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Circuit Protection Type

    overcurrent all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...