Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations and 2500.0 dc all locations

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Reset Method

    manual

  • Body Width

    3.343 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations and 250.0 dc all locations

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Arc Quenching Method

    air

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 200.000 maximum at 200 pct all locations

  • Frequency In Hertz

    60.0 all locations

  • Specification/Standard Data

    81349-mil-c-17361/1 government specification

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.625 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.938 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.125 inches nominal

  • Boss Height

    0.125 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations and 40.0 amperes dc all locations

  • Terminal Type And Quantity

    6 quick disconnect, male

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    2.625 inches nominal

  • Body Height

    3.375 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.216 inches nominal

  • Body Length

    4.125 inches nominal

  • Special Features

    circuit breaker supplier with two 12-24 mounting screws 4.125 in. lg

  • Case Material

    plastic

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-17361 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...