PL675-80866

Circuit Breakers

CIRCUIT BREAKER

PL675-80866

5925-01-234-8313

5925 - Circuit Breakers

The Boeing Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    4 threaded stud

  • Frequency In Hertz

    60.0

  • Inclosure Protection Type For Which Designed

    dustproof

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Circuit Protection Type

    overcurrent

  • Maximum Continuous Load Current Rating Per Pole

    12.5 amperes dc

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Case Material

    plastic

  • Body Width

    1.490 inches minimum and 1.510 inches maximum

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    2

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Thread Series Designator

    unc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 20.000 maximum at 200 pct

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct and 8.000 maximum at 200 pct

  • External Actuator Linkage Arrangement

    one and two linked

  • Actuator Position Designation

    at each pole

  • Manual Actuator Type And Quantity

    2 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    magnetic-hydraulic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...