F13919
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
F13919
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Principal Circuitry Type Per Function
inductance-capacitance 5th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Maximum Voltage Drop Per Function
1.15 volts ac 5th radio interference
-
Operating Current Rating Per Function In Amps
3.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Maximum Dielectric Withstanding Dc Voltage
230.0 volts at sea level
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
5 screw input 1st function
-
Operating Current Rating Per Function In Amps
3.0 2nd radio interference
-
Special Features
five filtered functions
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.500 inches nominal
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Functional Terminal Type And Quantity
5 screw output 2nd function
-
Mounting Facility Type And Quantity
4 threaded hole
-
Body Material
metal
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Overall Height
4.000 inches nominal
-
Maximum Voltage Drop Per Function
1.15 volts ac 1st radio interference
-
Operating Current Rating Per Function In Amps
3.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference
-
Body Width
2.000 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Maximum Voltage Drop Per Function
1.15 volts ac 4th radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 4th radio interference 4th function
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.125 inches nominal
-
Body Length
5.120 inches nominal
-
Power Line Frequency Rating Per Function In Hertz
60.0 5th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Mounting Facility Screw Thread Series Designator
unc
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
3.0 4th radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Vibration Resistance Range In Hertz
+10.0/+500.0
-
Operating Current Rating Per Function In Amps
3.0 5th radio interference
-
Body Height
3.500 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Maximum Voltage Drop Per Function
1.15 volts ac 3rd radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
-
Nominal Thread Size
0.138 inches
-
Inclosure Type
encased
-
Maximum Voltage Drop Per Function
1.15 volts ac 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 4th radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 5th radio interference 5th function
-
Maximum Temp Rise
25.0 deg celsius