77C719792
Coils and Transformers
TRANSFORMER,POWER
77C719792
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Cubic Measure (Non-Core)
66.9 cubic inches
-
Transformer Winding Connection Type
delta-wye
-
Terminal Type And Quantity
13 tab, solder lug
-
Thread Direction (Non-Core)
err-070
-
Mounting Facility Quantity
4 single group
-
Maximum Operating Temp
65.0 deg celsius
-
Center To Center Distance Between Mounting Facilities Parallel To Width
3.000 inches nominal single mounting facility single center group
-
Inclosure Type
open
-
Winding Operating Voltage
398.00 ac volts nominal single component single secondary and 419.00 ac volts nominal single component single secondary and 440.00 ac volts nominal single component single secondary
-
Overall Width
4.250 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.750 inches nominal single mounting facility single center group
-
Winding Operating Voltage
416.00 ac volts nominal single component single primary
-
Winding Shielding Method
internal shield grounded to core single component and internal shield grounded to inclosure single component
-
Winding Tap Location (Non-Core)
err-070
-
Overall Height
3.000 inches maximum
-
Mounting Method
threaded hole single group
-
Thread Series Designator
unf single group
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Input-Output Phase Relationship
three phase to three phase single component
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Winding Power Rating
900.0 volts-amperes single component single secondary
-
Thread Class (Non-Core)
err-070
-
Overall Length
5.250 inches maximum
-
Nominal Thread Size
0.190 inches single group