M39016/11-021L
Relays and Solenoids
RELAY,ELECTROMAGNETIC
M39016/11-021L
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-39016 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Criticality Code Justification
feat
-
Environmental Protection
hermetic and dustproof
-
Storage Type
general purpose warehouse
-
Fragility Factor
moderately rugged
-
~1
data on certain environmental and performanc
-
Time Delay
0.002 seconds maximum fixed release time
-
Overall Diameter
0.275 inches minimum and 0.335 inches maximum
-
Duty Type
continuous
-
Specification/Standard Data
81349-mil-r-39016/11 government specification
-
Operating Voltage Rating And Type At Specified Temp
12.0 volts dc 25 deg celsius single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
200.0 milliamperes dc inductive load
-
Coil Quantity
1
-
Terminal Type And Quantity
8 wire lead all functions
-
Purpose For Which Designed
general
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Special Features
failure rate 3.0 percent
-
Time Delay
0.004 seconds maximum fixed operate time
-
Mounting Facility Type And Quantity
1 terminal single mounting facility
-
Cubic Measure
0.033 cubic inches
-
Main Contact Load Current Rating At Maximum Rated Voltage
100.0 milliamperes dc lamp load
-
Winding Dc Resistance Rating
850.0 ohms nominal single winding
-
Winding Quantity
1
-
Overall Length
0.375 inches maximum
-
Main Contact Load Current Rating At Maximum Rated Voltage
500.0 milliamperes ac resistive load and 1.0 amperes dc resistive load
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary