Technical Characteristics

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    200.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Special Features

    voltage coil trips at28 vdc

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    2 threaded stud

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and 14.000 maximum at 200 pct

  • Unpackaged Unit Weight

    0.562 pounds

  • Thread Series Designator

    unc

  • Body Style

    single pole type

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    relay trip

  • Nominal Thread Size

    0.138 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...