RF10420

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

RF10420

5915-01-236-0569

5915 - Filters and Networks

Rfi Corporation

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Dielectric Withstanding Dc Voltage

    1.0 kilovolts at sea level

  • Body Height

    11.000 inches nominal

  • Overall Length

    9.000 inches nominal

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Maximum Voltage Drop Per Function

    2.5 volts ac 1st radio interference

  • Body Surface Treatment

    tin

  • Maximum Voltage Drop Per Function

    2.5 volts ac 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    208.0 volts ac 3rd radio interference 3rd function

  • Maximum Voltage Drop Per Function

    2.5 volts ac 5th radio interference

  • Mounting Facility Screw Thread Series Designator

    unef

  • Maximum Voltage Drop Per Function

    2.5 volts ac 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Average Power Rating Per Function

    600.0 watts 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    5 threaded stud output 2nd function

  • Unpackaged Unit Weight

    12.000 pounds

  • Nominal Thread Size

    0.750 inches

  • Average Power Rating Per Function

    3.6 kilowatts 1st radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 3rd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 4th radio interference

  • Inclosure Type

    hermetically sealed

  • Power Line Frequency Rating Per Function In Hertz

    60.0 5th radio interference

  • Maximum Voltage Drop Per Function

    2.5 volts ac 3rd radio interference

  • Average Power Rating Per Function

    600.0 watts 5th radio interference

  • Overall Height

    11.620 inches nominal

  • Average Power Rating Per Function

    3.6 kilowatts 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Average Power Rating Per Function

    3.6 kilowatts 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 4th radio interference 4th function

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Operating Current Rating Per Function In Amps

    10.0 2nd radio interference

  • Average Life Rating In Hours

    125000.0

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Operating Temp Range

    -0.0/+60.0 deg celsius

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 5th radio interference 5th function

  • Operating Current Rating Per Function In Amps

    10.0 3rd radio interference

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Mounting Facility Type And Quantity

    5 threaded bushing

  • End Item Identification

    door rlr cutn

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Operating Voltage Rating And Type Per Function

    208.0 volts ac 1st radio interference 1st function

  • Functional Terminal Type And Quantity

    5 threaded stud input 1st function

  • Style Designator

    rectangular terminal/terminals on two surfaces

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    208.0 volts ac 2nd radio interference 2nd function

  • Power Line Frequency Rating Per Function In Hertz

    60.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    10.0 1st radio interference

  • Body Width

    1.870 inches nominal

  • Body Length

    7.000 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...