UPL-11-1R0-9851-1

Circuit Breakers

CIRCUIT BREAKER

UPL-11-1R0-9851-1

5925-01-236-1017

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 65.0 dc

  • Nominal Thread Size

    0.138 inches

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Circuit Protection Type

    overvoltage second location

  • Trip Release Characteristic

    instantaneous second location

  • Manual Actuator Type And Quantity

    2 toggle

  • Frequency In Hertz

    50.0 first location or 60.0 first location

  • Body Width

    1.515 inches maximum

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac first location

  • Inclosure Protection Type For Which Designed

    shock resistant and moisture resistant and salt spray proof and vibration resistant

  • Unpackaged Unit Weight

    7.400 ounces

  • Terminal Type And Quantity

    4 threaded stud

  • External Actuator Linkage Arrangement

    one and two linked

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Pole Quantity

    2

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    200.0 first location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Mounting Surface To Terminal End Distance

    2.490 inches maximum

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 dc second location

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Thread Quantity Per Inch

    32

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Switch Current Rating And Type In Amps

    10.0 ac and 10.0 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct first location and 15.000 maximum at 200 pct first location

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Characteristic

    time delay first location

  • Switch Contact Arrangement

    single pole, double throw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...