6363-1-2

Circuit Breakers

CIRCUIT BREAKER

6363-1-2

5925-01-238-8562

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 30.000 maximum at 200 pct single location

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac single location and 2.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 30.0 dc single location

  • Mounting Surface To Terminal End Distance

    1.405 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    600.0 ac single location and 900.0 dc single location

  • Body Style

    single pole type

  • Trip Release Ambient Temp Rating

    25.0 deg fahrenheit nominal single location

  • Frequency In Hertz

    60.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.765 inches nominal

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Inclosure Protection Type For Which Designed

    dustproof

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Body Length

    2.203 inches nominal

  • Unpackaged Unit Weight

    1.800 ounces

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Circuit Protection Type

    overcurrent single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.437 inches nominal

  • Trip Release Method

    thermal single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Release Characteristic

    time delay single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...