FS320015A-SFC

Circuit Breakers

CIRCUIT BREAKER

FS320015A-SFC

5925-01-239-9653

5925 - Circuit Breakers

Drs Power & Control Technologies

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    6.125 inches nominal

  • Body Height

    3.500 inches nominal

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.218 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    general purpose

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Frequency In Hertz

    60.0 all locations

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 bus bar

  • Body Style

    9b multipole-single actuator type

  • Body Width

    4.125 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.500 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.500 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.688 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.150 inches nominal

  • Special Handling Feature

    magnetic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    22000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.164 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...