27-10012-5

Circuit Breakers

CIRCUIT BREAKER

27-10012-5

5925-01-240-1827

5925 - Circuit Breakers

The Boeing Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.250 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Body Length

    2.187 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc single location

  • Body Width

    0.750 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.187 inches nominal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.816 inches nominal

  • Terminal Type And Quantity

    2 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    27.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location and 6000.0 dc single location

  • Body Style

    single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...