4017111
Coils and Transformers
TRANSFORMER,POWER
4017111
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Transformer Winding Connection Type
wye-wye
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Body Length
3.630 inches maximum
-
Inclosure Type
fully inclosed
-
Mounting Method
threaded hole single group
-
Thread Direction
right-hand single group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.188 inches nominal single mounting facility single center group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.938 inches nominal single mounting facility single center group
-
Overall Width
3.630 inches maximum
-
Winding Tap Location
neutral tap single component single primary
-
Winding Operating Current
1.5 amperes dc nominal single component 2nd secondary
-
Thread Class
2b single group
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Input-Output Phase Relationship
three phase to six phase single component
-
Maximum Transformer Power Rating
245.5 volt-ampere single component
-
Body Height
2.000 inches maximum
-
Winding Power Rating
173.0 volts-amperes single component 1st secondary
-
Winding Power Rating
59.7 volts-amperes single component 2nd secondary
-
Winding Operating Voltage
23.00 dc volts nominal single component 2nd secondary
-
Unpackaged Unit Weight
3.500 pounds
-
Thread Series Designator
unc single group
-
Mounting Facility Quantity
4 single group
-
Winding Tap Location
neutral tap single component 1st secondary
-
Winding Tap Location
neutral tap single component 2nd secondary
-
Winding Function And Quantity
1 primary and 3 secondary single component
-
Nominal Thread Size
0.164 inches single group
-
Winding Tap Location
center tap single component 3rd secondary
-
Winding Operating Current
1.5 amperes dc nominal single component 3rd secondary
-
Winding Operating Current
5.0 amperes dc nominal single component 1st secondary
-
Winding Power Rating
12.8 volts-amperes single component 3rd secondary
-
Winding Operating Voltage
20.00 dc volts nominal single component 1st secondary
-
Winding Operating Voltage
400.00 ac volts nominal single component single primary
-
Winding Operating Voltage
8.50 dc volts nominal single component 3rd secondary
-
Terminal Type And Quantity
22 turret