ST86D17-2

Circuit Breakers

CIRCUIT BREAKER

ST86D17-2

5925-01-240-8034

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.984 inches minimum and 1.000 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    80.0 amperes ac all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.800 minimum at 200 pct all locations and 120.000 maximum at 200 pct

  • Frequency In Hertz

    60.0 all locations

  • Body Style

    6c multipole-multiple actuator type

  • Body Length

    3.250 inches minimum and 3.310 inches maximum

  • Body Width

    3.954 inches minimum and 4.030 inches maximum

  • Body Height

    2.330 inches minimum and 2.390 inches maximum

  • Case Material

    plastic

  • Boss Height

    0.150 inches minimum and 0.210 inches maximum

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    3 terminal

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    general purpose

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Special Features

    includes a 120-240 vac shunt trip device

  • Terminal Type And Quantity

    3 compression and 3 tab, solder lug

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...