9124-10238
Relays and Solenoids
RELAY,ELECTROMAGNETIC
9124-10238
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
12 threaded stud all functions
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac resistive load and 5.0 amperes dc
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac inductive load and 5.0 amperes dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac motor load and 50.0 amperes dc
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius all windings
-
Nominal Operating Current Rating And Type
0.6 amperes dc all windings
-
Mounting Facility Pattern
four position rectangular single mounting facility
-
Frequency In Hertz
400.0 nominal
-
Environmental Protection
shock resistant and vibration resistant
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.687 inches nominal single mounting facility
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.250 inches nominal single mounting facility
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
1.0 amperes ac lamp load and 1.0 amperes dc
-
Main Contact Maximum Voltage Rating In Volts
200.0 ac and 28.0 dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac resistive load and 50.0 amperes dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac inductive load and 50.0 amperes dc
-
Auxiliary Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Nonpile-Up Main Contact Arrangement
3 pole, single throw, normally open, double make, momentary action
-
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
-
Winding Quantity
1
-
Unthreaded Mounting Hole Diameter
0.218 inches nominal single mounting facility