AS26574

Circuit Breakers

CIRCUIT BREAKER

AS26574

5925-01-240-9179

5925 - Circuit Breakers

Society Of Automotive Engineers Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Body Width

    0.562 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Specification/Standard Data

    96906-ms26574 government specification

  • Bushing Length

    0.375 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    un

  • Center To Center Distance Between Terminals Parallel To Length

    0.593 inches nominal

  • Case Material

    plastic

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performance

  • Body Length

    0.750 inches nominal

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location and 500.0 dc single location

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    1.525 inches maximum

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...