Technical Characteristics
-
Winding Operating Voltage
10.80 ac volts nominal single component 1st secondary
-
Winding Tap Location (Non-Core)
err-070
-
Body Outside Diameter
2.000 inches nominal
-
Mounting Method
threaded hole single group
-
Inclosure Type
fully inclosed
-
Winding Operating Voltage
50.40 ac volts nominal single component 2nd secondary
-
Reliability Indicator
not established
-
Input-Output Phase Relationship
single phase to single phase single component
-
Frequency Rating
60.0 hertz nominal single component
-
Winding Operating Voltage
16.80 ac volts nominal single component 4th secondary
-
Mounting Facility Quantity
1 single group
-
Thread Series Designator
unc single group
-
Winding Operating Voltage
35.00 ac volts nominal single component single primary
-
Terminal Type And Quantity
19 wire lead
-
Winding Operating Voltage
36.00 ac volts nominal single component 3rd secondary
-
Winding Operating Current
1.1 amperes ac maximum single component 3rd secondary
-
Thread Direction (Non-Core)
err-070
-
Body Length
1.000 inches maximum
-
Special Features
six secondaries
-
Nominal Thread Size
0.138 inches single group
-
Winding Operating Current
200.0 milliamperes ac maximum single component 2nd secondary
-
Winding Operating Current
400.0 milliamperes ac maximum single component 1st secondary
-
Winding Operating Current
3.7 amperes ac maximum single component 4th secondary
-
Winding Function And Quantity
1 primary single component and 6 secondary single component