AE11302
Coils and Transformers
TRANSFORMER,POWER
AE11302
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.797 inches minimum single mounting facility single center group and 2.827 inches maximum single mounting facility single center group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Maximum Operating Temp
130.0 deg celsius
-
Winding Shielding Method
internal shield grounded to core single component
-
Winding Operating Current
1.5 amperes ac nominal single component single secondary
-
Mounting Slot Width
0.190 inches nominal single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.985 inches minimum single mounting facility single center group and 2.015 inches maximum single mounting facility single center group
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Terminal Type And Quantity
5 tab, solder lug
-
Test Data Document
04655-50-511245 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Body Length
3.500 inches maximum
-
Winding Operating Voltage
36.00 ac volts nominal single component single secondary
-
Mounting Method
slot single group
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4 single group
-
Body Width
2.440 inches minimum and 2.560 inches maximum
-
Frequency Rating
50.0 hertz minimum single component and 400.0 hertz maximum single component
-
Body Height
3.000 inches maximum