UPGH-66-1-41-502-01

Circuit Breakers

CIRCUIT BREAKER

UPGH-66-1-41-502-01

5925-01-243-9901

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    110.0 ac all locations

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Boss Height

    0.130 inches nominal

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Unpackaged Unit Weight

    6.600 ounces

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 5.000 maximum at 200 pct all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Manual Actuator Type And Quantity

    2 toggle

  • Frequency In Hertz

    400.0 all locations

  • Body Width

    1.515 inches maximum

  • Terminal Type And Quantity

    4 quick disconnect, male

  • External Actuator Linkage Arrangement

    one and two linked

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...