4310-050-20

Circuit Breakers

CIRCUIT BREAKER

4310-050-20

5925-01-245-2002

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Body Width

    0.593 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.490 inches minimum and 0.510 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Nominal Thread Size

    0.438 inches

  • Thread Quantity Per Inch

    32

  • Bushing Length

    0.240 inches minimum and 0.260 inches maximum

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Special Features

    weapon system essential

  • Actuator Function

    trip-reset

  • Criticality Code Justification

    feat

  • Storage Type

    general purpose warehouse

  • Body Length

    0.781 inches maximum

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Fragility Factor

    moderately rugged

  • Inclosure Protection Type For Which Designed

    corrosion resistant and moisture resistant

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...