34134
Coils and Transformers
TRANSFORMER,RADIO FREQUENCY
34134
TRANSFORMER,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Terminal Type And Quantity
6 wire lead
-
Mounting Method
unthreaded hole single group
-
Body Length
1.500 inches maximum
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Body Outside Diameter
2.340 inches maximum
-
Reliability Indicator
not established
-
Mounting Facility Quantity
1 single group
-
Rating Method
winding turns single component single primary
-
Turn Quantity
40 single component single primary
-
Rating Method
winding turns single component single secondary
-
Winding Conductor Size
0.03589 inches american wire gage single component single primary
-
Inclosure Type
fully inclosed
-
Mounting Hole Diameter
0.216 inches nominal single group
-
Winding Conductor Size
0.03196 inches american wire gage single component single secondary
-
Frequency Rating
40.0 kilohertz nominal single component
-
Turn Quantity
44 single component single secondary
-
Maximum Operating Temp
65.0 deg celsius