9124-10243
Relays and Solenoids
RELAY,ELECTROMAGNETIC
9124-10243
Leach International Corporation
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Main Contact Load Current Rating At Maximum Rated Voltage
15.0 amperes ac resistive load and 50.0 amperes dc resistive load
-
Mounting Facility Pattern
rectangular single mounting facility
-
Storage Type
general purpose warehouse
-
Main Contact Load Current Rating At Maximum Rated Voltage
15.0 amperes ac inductive load and 50.0 amperes dc inductive load
-
Duty Type
continuous
-
Time Delay
0.05 seconds maximum fixed release time
-
Nonpile-Up Auxiliary Contact Arrangement
2 pole, single throw, normally open, momentary action
-
Coil Quantity
1
-
Purpose For Which Designed
general
-
Nominal Operating Current Rating And Type
200.0 milliamperes ac single winding
-
Overall Width
3.150 inches nominal
-
Nonpile-Up Main Contact Arrangement
3 pole, single throw, normally open, momentary action
-
Time Delay
0.03 seconds maximum fixed operate time
-
Terminal Type And Quantity
12 threaded stud all functions
-
Environmental Protection
dustproof and shock resistant and vibration resistant
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.677 inches minimum single mounting facility and 2.697 inches maximum single mounting facility
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
1.0 amperes ac lamp load and 1.0 amperes dc lamp load
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac inductive load and 5.0 amperes dc inductive load
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.240 inches minimum single mounting facility and 3.260 inches maximum single mounting facility
-
Winding Quantity
1
-
Arc Quenching Method
air
-
Main Contact Load Current Rating At Maximum Rated Voltage
12.0 amperes ac motor load and 50.0 amperes dc motor load
-
Frequency In Hertz
60.0 nominal or 400.0 nominal
-
Main Contact Maximum Voltage Rating In Volts
440.0 ac and 28.0 dc
-
Auxiliary Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Operating Voltage Rating And Type At Specified Temp
115.0 volts ac 25 deg celsius single winding
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
-
Overall Height
2.297 inches minimum and 2.485 inches maximum
-
Unthreaded Mounting Hole Diameter
0.213 inches minimum single mounting facility and 0.223 inches maximum single mounting facility
-
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
-
Fragility Factor
moderately rugged
-
Overall Length
3.730 inches maximum