CF1-G8-DU-5-120/240-20

Circuit Breakers

CIRCUIT BREAKER

CF1-G8-DU-5-120/240-20

5925-01-246-4516

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    corrosion resistant and fungus resistant

  • Unpackaged Unit Weight

    9.000 ounces

  • Features Provided

    high inrush protection

  • Case Material

    plastic

  • Body Length

    5.844 inches nominal

  • Special Handling Feature

    magnetic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 18.000 maximum at 200 pct single location

  • Mounting Surface To Terminal End Distance

    2.610 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Body Width

    1.026 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Boss Height

    0.218 inches nominal

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.844 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 240.0 dc single location

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...