RJR50FP101P
Resistors
RESISTOR,VARIABLE,NONWIRE WOUND,NONPRECISION
RJR50FP101P
RESISTOR,VARIABLE,NONWIRE WOUND,NONPRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-39035 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performanc
-
Body Length
0.250 inches maximum
-
Maximum Running Torque
2.00 inch-ounces
-
Section Quantity
1
-
Body Style
rectangular
-
Specification/Standard Data
81349-mil-r-39035/4 government specification
-
Reliability Failure Rate Level In Percent
0.100
-
Terminal Type And Quantity
3 pin
-
Features Provided
humidity proof
-
Resistance Tolerance Per Section In Percent
-10.0/+10.0 single section
-
Standard Taper Curve Per Section
a single section
-
Rotary Actuator Travel In Angular Deg
215.0 minimum
-
Ambient Temp In Deg Celsius Per Section At Full Rated Power
85.0 single section
-
Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius
-100.0/+100.0 single section
-
Effective Electrical Rotation In Deg Angular Rotation
215.0 minimum
-
Body Height
0.250 inches nominal
-
Reliability Indicator
established
-
Body Width
0.250 inches nominal
-
Electrical Resistance Per Section
100.000 ohms c and better flooring
-
Terminal Length
0.172 inches minimum
-
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
150.0 single section
-
Actuator Type
flush drive with slot-hole
-
Shaft Bearing Type
sleeve
-
Power Dissipation Rating Per Section In Watts
0.25 7th secondary quality
-
Maximum Starting Torque
2.00 inch-ounces
-
Cubic Measure
0.016 cubic inches
-
Center To Center Distance Between Terminals
0.200 inches nominal
-
Maximum Stop Torque
4.00 inch-ounces
-
Mounting Method
terminal
-
Terminal Location
rear end
-
Fragility Factor
moderately rugged
-
Actuator Travel Control Feature
stops
-
Center To Center Distance Between Center Terminal And Outside Terminal
0.100 nominal inches