6363-2-5

Circuit Breakers

CIRCUIT BREAKER

6363-2-5

5925-01-247-5947

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.203 inches nominal

  • Body Width

    0.765 inches nominal

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.031 inches nominal

  • Arc Quenching Method

    air

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 30.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    600.0 ac single location and 600.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 40.000 maximum at 200 pct

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Style

    4a single pole type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.437 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    general purpose

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...