M39016-40-010
Relays and Solenoids
RELAY,ELECTROMAGNETIC
M39016-40-010
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performanc
-
Special Features
failure rate level 1.0 percent
-
Duty Type
continuous
-
Time Delay
0.005 seconds maximum fixed operate and release time
-
Main Contact Load Current Rating At Maximum Rated Voltage
200.0 milliamperes dc lamp load
-
Operating Voltage Rating And Type At Specified Temp
12.0 volts dc 25 deg celsius single winding
-
Terminal Type And Quantity
14 pin all functions
-
Coil Quantity
1
-
Overall Height
0.577 inches nominal
-
Environmental Protection
hermetic and shock resistant and vibration resistant
-
Test Data Document
81349-mil-r-39016 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Nonpile-Up Main Contact Arrangement
4 pole, double throw, one position momentary
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
300.0 milliamperes ac resistive load and 2.0 amperes dc resistive load
-
Specification/Standard Data
81349-mil-r-39016/40 government specification
-
Mounting Facility Type And Quantity
1 terminal single mounting facility
-
Winding Quantity
1
-
Overall Length
0.800 inches nominal
-
Criticality Code Justification
feat
-
Winding Dc Resistance Rating
100.0 ohms nominal single winding
-
Overall Width
0.390 inches nominal