AM3-A39-A-40-252
Circuit Breakers
CIRCUIT BREAKER
AM3-A39-A-40-252
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Method
thermal-magnetic all locations
-
Body Width
2.240 inches minimum and 2.510 inches maximum
-
Ultimate Trip Time Per Pole In Seconds
10.000 nominal all locations
-
Trip Release Ambient Temp Rating
77.0 deg fahrenheit nominal all locations
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Frequency In Hertz
60.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
40.0 amperes ac all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Mounting Facility Type And Quantity
6 threaded stud
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Case Material
plastic
-
Reset Method
manual
-
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Special Features
function: circuit breaker, magnetic, 40 amp; reference data: cb-4401, instruction book arsr-1d/e/f, vol 5, sec 10, pg 10-759; cb-4401, instruction book arsr-2, vol 5, sec 10, pg 10-563
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Terminal Type And Quantity
9 tab, solder lug or 6 threaded stud
-
End Item Identification
air route surveillance radar 1, fa7171 amplitron power supply cabinet; arsr-2, fa7121 amplitron power supply cabinet
-
Body Style
multipole-multiple actuator type
-
Fragility Factor
moderately rugged
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 all locations
-
Trip Release Characteristic
instantaneous all locations
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Inclosure Protection Type For Which Designed
dustproof
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole