Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
End Item Identification
c5b acft; wsd: aircraft, galaxy c-5
-
Winding Conductor Size
0.02535 inches american wire gage 4th component single primary
-
Inductance Rating
90.00 microhenries minimum 2nd component single winding and 3.10 millihenries maximum 2nd component single winding
-
Winding Function And Quantity
1 primary 3rd component and 6 secondary 3rd component
-
Body Width
2.010 inches maximum
-
Winding Function And Quantity
1 primary 4th component and 1 secondary 4th component
-
Turn Quantity
500 4th component single secondary
-
Turn Quantity
105 2nd component single winding
-
Turn Quantity
1 4th component single primary
-
Winding Operating Voltage
2.50 ac pounds per hour wet 3rd component 1st secondary
-
Winding Operating Voltage
2.00 ac pounds per hour wet 2nd component single winding
-
Criticality Code Justification
feat
-
Rating Method
electrical 3rd component 2nd secondary and winding turns 3rd component 2nd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.500 inches nominal single mounting facility single center group
-
Special Features
weapon system essential
-
Winding Conductor Size
0.01594 inches american wire gage 3rd component 3rd secondary
-
Rating Method
electrical 3rd component 1st secondary and winding turns 3rd component 1st secondary
-
Turn Quantity
32 3rd component single primary
-
Winding Conductor Size
0.02535 inches american wire gage 3rd component single primary
-
Body Height
1.630 inches maximum
-
Winding Conductor Size
0.01594 inches american wire gage 3rd component 4th secondary
-
Dc Resistance Rating In Ohms
0.132 3rd component 1st secondary
-
Winding Conductor Size
0.00500 inches american wire gage 4th component single secondary
-
Dc Resistance Rating In Ohms
0.046 3rd component single primary
-
Turn Quantity
12 3rd component 3rd secondary
-
Turn Quantity
4 3rd component 1st secondary
-
Winding Shielding Method
internal shield grounded to terminal 3rd component
-
Dc Resistance Rating In Ohms
0.240 3rd component 4th secondary
-
Rating Method
electrical 2nd component single winding and winding turns 2nd component single winding
-
Inductance Rating
10.00 microhenries nominal 1st component single winding
-
Winding Operating Voltage
30.00 ac pounds per hour wet 3rd component 2nd secondary
-
Winding Conductor Size
0.01594 inches american wire gage 3rd component 1st secondary
-
Winding Operating Voltage
20.00 ac pounds per hour wet 3rd component single primary
-
Dummy Terminal Quantity (Non-Core)
4
-
Rating Method
electrical 1st component single winding and winding turns 1st component single winding
-
Winding Operating Voltage
0.10 ac pounds per hour wet 1st component single winding
-
Dc Resistance Rating In Ohms
0.120 3rd component 3rd secondary
-
Winding Conductor Size
0.01594 inches american wire gage 3rd component 2nd secondary
-
Winding Operating Voltage
7.48 ac pounds per hour wet 3rd component 3rd secondary
-
Rating Method
winding turns 4th component single primary
-
Dc Resistance Rating In Ohms
0.760 3rd component 2nd secondary
-
Terminal Type And Quantity
28 turret
-
Winding Conductor Size
0.02257 inches american wire gage 2nd component single winding
-
Turn Quantity
48 3rd component 2nd secondary
-
Rating Method
winding turns 4th component single secondary
-
Frequency Rating
20.0 kilohertz nominal 2nd component
-
Frequency Rating
20.0 kilohertz nominal 3rd component
-
Input-Output Phase Relationship
single phase to single phase 3rd component
-
Frequency Rating
20.0 kilohertz nominal 4th component
-
Reliability Indicator
not established
-
Input-Output Phase Relationship
single phase to single phase 4th component
-
Winding Operating Current
29.0 amperes maximum of standard range b and better drop siding 2nd component single winding
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.800 inches nominal single mounting facility single center group
-
Rating Method
electrical 3rd component 3rd secondary and winding turns 3rd component 3rd secondary
-
Winding Operating Voltage
15.60 ac pounds per hour wet 3rd component 4th secondary
-
Body Length
3.300 inches maximum
-
Rating Method
electrical 3rd component 4th secondary and winding turns 3rd component 4th secondary
-
Frequency Rating
400.0 hertz nominal 1st component
-
Winding Conductor Size
0.00200 inches american wire gage 1st component single winding
-
Turn Quantity
7 1st component single winding
-
Turn Quantity
25 3rd component 4th secondary
-
Rating Method
electrical 3rd component single primary and winding turns 3rd component single primary
-
Mounting Method
threaded hole single group
-
Winding Tap Location (Non-Core)
center tap 3rd component 2nd secondary
-
Winding Operating Current
30.0 amperes maximum of standard range b 1st component single winding
-
Inclosure Type
fully inclosed
-
Winding Tap Location (Non-Core)
center tap 3rd component 3rd secondary
-
Dc Resistance Rating In Ohms
14.000 4th component single secondary
-
Winding Tap Location (Non-Core)
center tap 3rd component 4th secondary