295-111-1REC2-63-4313-1
Circuit Breakers
CIRCUIT BREAKER
295-111-1REC2-63-4313-1
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Series Designator
unc and unf
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
0.5 amperes ac all locations
-
Inclosure Protection Type For Which Designed
shock resistant and moisture resistant and vibration resistant and corrosion resistant
-
Mounting Surface To Terminal End Distance
2.475 inches nominal
-
Ultimate Trip Time Per Pole In Seconds
700.000 maximum all locations
-
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac all locations and 480.0 ac all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Switch Terminal Type
quick disconnect, male
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Auxiliary Switch Function And Quantity
1 control
-
Body Length
2.490 inches nominal
-
Terminal Type And Quantity
6 threaded stud
-
Trip Delay Time In Seconds Per Rated Continuous Current
80.000 minimum at 125 pct all locations and 700.000 maximum at 125 pct all locations and 0.010 minimum at 1000 pct all locations and 0.100 maximum at 1000 pct all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Switch Voltage Rating And Type In Volts
250.0 ac
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Boss Height
0.150 inches nominal
-
Mounting Facility Type And Quantity
6 threaded hole and 6 threaded stud and 3 terminal
-
Switch Current Rating And Type In Amps
10.0 ac
-
Trip Release Characteristic
time delay all locations
-
Internal Trip Release Configuration
series trip w/auxiliary load terminal third location
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Nominal Thread Size
0.138 inches and 0.190 inches
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Internal Trip Release Configuration
series trip first location
-
Switch Contact Arrangement
single pole, double throw
-
Internal Trip Release Configuration
series trip second location
-
Body Width
2.265 inches maximum
-
Switch Location And Position Designation
external at pole three
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal