7909329-00

Circuit Breakers

CIRCUIT BREAKER

7909329-00

5925-01-249-7546

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Pole Quantity

    2

  • Inclosure Protection Type For Which Designed

    dustproof

  • Circuit Protection Type

    overcurrent all locations

  • Fragility Factor

    moderately rugged

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Body Length

    1.562 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.150 minimum at 200 pct all locations and 7.000 maximum at 200 pct all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    1.187 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Body Style

    multipole-single actuator type

  • Terminal Type And Quantity

    4 wire hook

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Bushing Length

    0.360 inches maximum

  • Special Features

    two threaded holes 6-32 unc; 0.750 in. apart; for added mounting stability

  • Trip Release Method

    magnetic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac all locations

  • Arc Quenching Method

    air

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...