PEI 9412
Coils and Transformers
COIL,RADIO FREQUENCY
PEI 9412
COIL,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Core Construction
powdered single component
-
Adjustment Device Drive Type
slotted screw single component
-
Rating Method
electrical single component single winding and winding turns single component single winding
-
Adjustment Method And Quantity
1 adjustable core single component
-
Terminal Type And Quantity
2 pin
-
Inductance Rating
0.35 microhenries minimum single component single winding and 0.43 microhenries maximum single component single winding
-
Turn Quantity
6-3/4 single component single winding
-
Frequency At Which Inductance And Quality Factor Applies (Non-Core)
25.0 megahertz single component single winding
-
Minimum Self-Resonant Frequency (Non-Core)
220.0 megahertz single component
-
Quality Factor
70 minimum single component single winding
-
Mounting Method
tab single group
-
Body Length
0.400 inches nominal
-
Coil Form Type
hollow single component
-
Body Width
0.400 inches nominal
-
Winding Conductor Size
0.01003 inches american wire gage single component single winding
-
Inclosure Type
fully inclosed
-
Dc Resistance Rating In Ohms
0.073 single component single winding
-
Winding Operating Current
1.4 amperes maximum of standard range b and better drop siding single component single winding
-
Reliability Indicator
not established
-
Dummy Terminal Quantity (Non-Core)
2
-
Mounting Tab Width
0.050 inches nominal
-
Body Height
0.495 inches maximum