AP-112-1-49-252
Circuit Breakers
CIRCUIT BREAKER
AP-112-1-49-252
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Series Designator
unef
-
Terminal Type And Quantity
6 wire hook
-
Body Style
1b multipole-single actuator type
-
Case Material
metal
-
Arc Quenching Method
air
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
~1
lity
-
Bushing Length
0.380 inches nominal
-
Body Length
1.500 inches maximum
-
Body Width
1.875 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.675 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Pole Quantity
3
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Trip Release Characteristic
instantaneous all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
at pole one
-
Nominal Thread Size
0.375 inches
-
Special Features
equipped with two 6-32 threaded holes; 1.374 in. apart; for added mounting stabi
-
Frequency In Hertz
60.0