Technical Characteristics
-
~1
data on certain environmental and performanc
-
Test Data Document
81349-mil-r-39016 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Environmental Protection
vibration resistant and salt spray resistant and shock resistant and hermetic
-
Main Contact Load Current Rating At Maximum Rated Voltage
0.2 amperes dc inductive load
-
Frequency In Hertz
60.0 nominal
-
Terminal Type And Quantity
8 wire lead contacts
-
Overall Length
0.780 inches nominal
-
Specification/Standard Data
81349-mil-r-39016/15 government specification
-
Operating Voltage Rating And Type At Specified Temp
26.5 volts teardrop, two holes type 4f all windings
-
Main Contact Load Current Rating At Maximum Rated Voltage
0.1 amperes dc lamp load
-
Terminal Type And Quantity
1 pin ground
-
Coil Quantity
1
-
Overall Diameter
0.275 inches minimum and 0.335 inches maximum
-
Main Contact Maximum Voltage Rating In Volts
32.0 dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
1.0 amperes dc resistive load