M55629/20TL
Circuit Breakers
CIRCUIT BREAKER
M55629/20TL
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.130 minimum at 200 pct single location and 1.500 maximum at 200 pct single location
-
Thread Quantity Per Inch
32
-
Specification/Standard Data
81349-mil-c-55629/20 government specification
-
Circuit Protection Type
overcurrent single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location
-
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc
-
Switch Contact Arrangement
single pole, double throw
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Pole Quantity
1
-
Center To Center Distance Between Terminals Parallel To Length
1.499 inches minimum and 1.561 inches maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Mounting Surface To Terminal End Distance
2.201 inches minimum and 2.232 inches maximum
-
Body Style
single pole type
-
Body Width
0.735 inches minimum and 0.765 inches maximum
-
Body Length
1.969 inches minimum and 2.031 inches maximum
-
Terminal Type And Quantity
2 tab w/screw
-
Auxiliary Switch Function And Quantity
1 alarm
-
Thread Series Designator
un
-
Inclosure Protection Type For Which Designed
corrosion resistant and fungus resistant
-
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performanc
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Switch Terminal Type
tab, solder lug
-
Special Handling Feature
magnetic
-
Reset Method
manual
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Bushing Length
0.464 inches minimum and 0.526 inches maximum
-
Switch Location And Position Designation
internal at pole one
-
Case Material
plastic