UPL111-1-66F-253

Circuit Breakers

CIRCUIT BREAKER

UPL111-1-66F-253

5925-01-251-5016

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    1.937 inches nominal

  • Mounting Facility Type And Quantity

    6 threaded stud

  • Manual Actuator Type And Quantity

    3 toggle

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Terminal Type And Quantity

    6 threaded stud

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Surface To Terminal End Distance

    2.469 inches nominal

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • End Item Identification

    2 generation vortac (2gvortac)

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Boss Height

    0.187 inches nominal

  • Circuit Protection Type

    overvoltage all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.781 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Body Width

    2.250 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    2.500 inches nominal

  • Special Features

    reference data: 1cb1, fa-9996, ti-6820.2, vortac, vor/dme, vor eq., vol 8, sec 8, pg8-68

  • Trip Release Duty Cycle

    continuous all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Ultimate Trip Time Per Pole In Seconds

    50.000 minimum all locations and 700.000 maximum all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.781 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...