P119G-5HC12TS-X-2320
Switches
SWITCH,PRESSURE
P119G-5HC12TS-X-2320
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type
tab w/screw
-
Media For Which Designed
gas
-
Special Features
turn switch in clockwise direction will lower set point
-
Contact Load Current Rating
1.0 amperes resistive load second voltage and 500.0 milliamperes inductive load second voltage
-
Contact Adjustment Range
+3.00/+50.00 actuation point pounds per square inch gage and +2.00/+48.00 deactuation point pounds per square inch gage
-
Proof Pressure
50.00 pounds per square inch
-
Contact Voltage Rating In Volts
115.0 ac at sea level first voltage
-
Frequency In Hertz
60.0 first voltage
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Contact Adjustment Type
external actuation point hex nut and external deactuation point hex nut
-
Overall Length
1.969 inches nominal
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 225.0 deg fahrenheit maximum
-
Pressure Switch Type
gage
-
Contact Voltage Rating In Volts
28.0 dc at sea level second voltage
-
Contact Load Current Rating
1.0 amperes resistive load first voltage and 1.0 amperes inductive load first voltage
-
Body Length
1.500 inches nominal
-
Contact Action Stimulus
increase
-
Mounting Method
threaded bushing
-
Style Designator
cylindrical
-
Overall Diameter
1.094 inches nominal
-
Contact Adjustability
actuation point adjustable and deactuation point adjustable
-
Precious Material
gold
-
Precious Material And Location
terminals gold