2TC43-7.5

Circuit Breakers

CIRCUIT BREAKER

2TC43-7.5

5925-01-252-3914

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Current Rating And Type In Amps

    0.01 dc

  • Unpackaged Unit Weight

    1.500 ounces

  • Inclosure Protection Type For Which Designed

    corrosion resistant and explosion proof and sand resistant and salt spray proof and dustproof and fungus resistant and shock resistant

  • Manual Actuator Type And Quantity

    1 push button

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Fragility Factor

    moderately rugged

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1600.0 ac single location

  • Reset Method

    manual

  • Body Length

    0.880 inches maximum

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Actuator Function

    trip-reset

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.630 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Switch Terminal Type

    pin

  • Terminal Type And Quantity

    2 tab w/screw

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Series Designator

    un

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac single location

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and 0.531 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...