6510-002-35

Circuit Breakers

CIRCUIT BREAKER

6510-002-35

5925-01-254-2051

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Length

    4.260 inches maximum

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    75.0 deg fahrenheit nominal single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Overall Height

    1.200 inches maximum

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 28.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Overall Width

    3.250 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    16.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3600.0 ac single location and 3600.0 dc single location

  • Fragility Factor

    moderately rugged

  • Reset Method

    electric

  • Switch Terminal Type

    tab, solder lug

  • Inclosure Protection Type For Which Designed

    dustproof

  • Body Style

    rectangular dimensional envelope

  • Test Data Document

    81349-mil-c-83383 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Reset Actuator Voltage Rating And Type In Volts

    115.0 ac

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac single location and 35.0 amperes dc single location

  • Unthreaded Mounting Hole Diameter

    0.172 inches nominal

  • Specification/Standard Data

    81349-mil-c-83383/2 government specification

  • Switch Current Rating And Type In Amps

    3.0 ac and 3.0 dc

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • ~1

    data on certain environmental and performanc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...