LS10158-35
Circuit Breakers
CIRCUIT BREAKER
LS10158-35
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
series trip single location
-
Circuit Protection Type
overcurrent single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Trip Release Characteristic
time delay single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Mounting Surface To Terminal End Distance
1.281 inches minimum and 1.378 inches maximum
-
Thread Series Designator
uns
-
Actuator Function
trip-reset
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac single location
-
Trip Release Method
magnetic single location
-
Terminal Type And Quantity
2 tab w/screw
-
Ultimate Trip Time Per Pole In Seconds
60.000 maximum single location
-
Reset Method
manual
-
Body Style
single pole type
-
Body Length
1.094 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.673 inches minimum and 0.805 inches maximum
-
Case Material
plastic
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Nominal Thread Size
0.469 inches
-
Bushing Length
0.218 inches minimum and 0.281 inches maximum
-
Thread Quantity Per Inch
32
-
Body Width
0.750 inches maximum
-
Pole Quantity
1
-
Frequency In Hertz
420.0 single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 nominal at 500 pct single location
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location
-
Actuator Position Designation
at pole one