9291654-4

Circuit Breakers

CIRCUIT BREAKER

9291654-4

5925-01-254-4781

5925 - Circuit Breakers

U S Army Armament Research &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct single location and 1.400 maximum at 200 pct single location

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Thread Series Designator

    unef

  • Body Length

    1.969 inches minimum and 2.031 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Inclosure Protection Type For Which Designed

    dustproof

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • End Item Identification

    1095-00-397-3456

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    2.094 inches minimum and 2.156 inches maximum

  • Nominal Thread Size

    0.375 inches

  • Bushing Length

    0.344 inches minimum and 0.406 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes dc single location

  • Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    1.529 inches minimum and 1.591 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...