0N332775-1
Circuit Breakers
CIRCUIT BREAKER
0N332775-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.150 minimum at 200 pct second location and 0.600 minimum at 200 pct first location and 7.000 maximum at 200 pct second location
-
Features Provided
high inrush protection
-
Bushing Length
0.380 inches maximum
-
Nonturn Device Length
0.130 inches nominal
-
Manual Actuator Type And Quantity
1 toggle
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac second location
-
Body Length
1.500 inches maximum
-
Actuator Position Designation
between pole one and two
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac second location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Body Width
1.250 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 maximum at 200 pct first location
-
Thread Series Designator
unef
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Actuator Function
trip-reset
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Internal Trip Release Configuration
series trip all locations
-
Nonturn Device Diameter
0.140 inches nominal
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Terminal Type And Quantity
4 wire hook
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc first location
-
Nonturn Device Location
at 3 oclock and at 9 oclock
-
Body Style
multipole-single actuator type
-
Nonturn Device Radius
0.625 inches nominal
-
Case Material
metal
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc first location
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant and corrosion resistant
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Frequency In Hertz
50.0 second location or 60.0 second location
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations