0N332775-1

Circuit Breakers

CIRCUIT BREAKER

0N332775-1

5925-01-254-6590

5925 - Circuit Breakers

National Security Agency

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.150 minimum at 200 pct second location and 0.600 minimum at 200 pct first location and 7.000 maximum at 200 pct second location

  • Features Provided

    high inrush protection

  • Bushing Length

    0.380 inches maximum

  • Nonturn Device Length

    0.130 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac second location

  • Body Length

    1.500 inches maximum

  • Actuator Position Designation

    between pole one and two

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac second location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Width

    1.250 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 maximum at 200 pct first location

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Internal Trip Release Configuration

    series trip all locations

  • Nonturn Device Diameter

    0.140 inches nominal

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Terminal Type And Quantity

    4 wire hook

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc first location

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Nonturn Device Radius

    0.625 inches nominal

  • Case Material

    metal

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc first location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and corrosion resistant

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Frequency In Hertz

    50.0 second location or 60.0 second location

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...