6451005D

Circuit Breakers

CIRCUIT BREAKER

6451005D

5925-01-254-9379

5925 - Circuit Breakers

Thales Training & Simulation Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 threaded stud

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Thread Series Designator

    unc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Body Style

    single pole type

  • Body Length

    2.461 inches minimum and 2.481 inches maximum

  • Trip Release Method

    magnetic-hydraulic single location

  • Frequency In Hertz

    60.0 single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Thread Quantity Per Inch

    32

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Trip Release Characteristic

    time delay single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...