PZ9LZ-M08C

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

PZ9LZ-M08C

5915-01-255-8278

5915 - Filters and Networks

Avx Filters Corp

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.600 inches nominal

  • Full Load Insertion Loss Frequencies In Megahertz

    50.0 and 0.1 and 0.5 and 0.0 and 0.2 and 100.0

  • Maximum Voltage Drop Per Function

    2.0 volts ac 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Operating Current Rating Per Function In Amps

    1.2 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    5.0 volts dc 6th radio interference 6th function

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Output Terminal Manufacturer Code

    96214

  • Operating Current Rating Per Function In Amps

    1.2 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Operating Current Rating Per Function In Amps

    0.76 6th radio interference

  • Maximum Voltage Drop Per Function

    0.04 kilovolts dc 6th radio interference

  • Operating Current Rating Per Function In Amps

    1.2 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Body Material

    metal

  • Special Features

    eleven filtered functions; six unfiltered functions

  • Maximum Dielectric Withstanding Dc Voltage

    30.0 volts at sea level

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 4th radio interference 4th function

  • Operating Temp Range

    -55.0/+85.0 deg celsius

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    0.5 4th radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle output 2nd function

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance-resistance 3rd radio interference

  • Unpackaged Unit Weight

    4.250 pounds

  • Inclosure Type

    hermetically sealed

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance-resistance 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Maximum Dielectric Withstanding Ac Rms Voltage

    230.0 volts at sea level

  • Features Provided

    moisture resistant and shock resistant

  • Operating Voltage Rating And Type Per Function

    15.0 volts dc 5th radio interference 5th function

  • Functional Terminal Type And Quantity

    1 connector, plug input 1st function

  • Maximum Voltage Drop Per Function

    0.075 kilovolts dc 5th radio interference

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 3rd radio interference 3rd function

  • Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    60.0 and 35.0 and 48.0 and 75.0 and 75.0 and 75.0

  • Input Terminal Identification

    sma-connector

  • Mounting Facility Screw Thread Series Designator

    unc

  • Principal Circuitry Type Per Function

    inductance-capacitance-resistance 1st radio interference

  • Input Terminal Manufacturer Code

    96214

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Style Designator

    rectangular terminal/terminals on two surfaces

  • Overall Height

    2.185 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Body Length

    6.000 inches maximum

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 2nd radio interference 2nd function

  • Body Width

    3.000 inches nominal

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 1st radio interference 1st function

  • Output Terminal Identification

    sma-receptacle

  • Operating Current Rating Per Function In Amps

    0.08 5th radio interference

  • Overall Length

    6.095 inches nominal

  • Body Surface Treatment

    tin

  • Maximum Voltage Drop Per Function

    2.0 volts dc 3rd radio interference

  • Body Height

    2.000 inches maximum

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Vibration Resistance Range In Hertz

    +10.0/+1000.0

  • Maximum Voltage Drop Per Function

    0.4 kilovolts dc 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Maximum Temp Rise

    25.0 deg celsius

  • Maximum Voltage Drop Per Function

    2.0 volts ac 1st radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...