5548503
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
5548503
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Temp Rise
25.0 deg celsius
-
Overall Height
4.750 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.375 inches nominal
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.187 inches nominal
-
Functional Terminal Type And Quantity
2 threaded stud output 2nd function
-
Unpackaged Unit Weight
7.000 pounds
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Input Terminal Identification
ms3400d22-22p
-
Average Power Rating Per Function
2.015 kilowatts 1st radio interference
-
Functional Terminal Type And Quantity
1 threaded stud ground 3rd function
-
Vibration Resistance Range In Hertz
+10.0/+500.0
-
Mounting Facility Type And Quantity
6 threaded hole
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Average Power Rating Per Function
2.015 kilowatts 2nd radio interference
-
Body Length
3.000 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
20.0 and 80.0 and 80.0 and 80.0 and 60.0 and 80.0
-
Maximum Voltage Drop Per Function
1.0 volts ac 2nd radio interference
-
Body Width
7.000 inches nominal
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Overall Length
3.750 inches nominal
-
Special Features
two filtered functions
-
Input Terminal Manufacturer Code
53711
-
Full Load Insertion Loss Frequencies In Megahertz
100.0 and 0.1 and 0.0 and 1.0 and 10.0 and 1000.0
-
Inclosure Type
hermetically sealed
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Features Provided
moisture resistant and shock resistant
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Operating Temp Range
+32.0/+122.0 deg fahrenheit
-
Maximum Dielectric Withstanding Ac Rms Voltage
1.0 kilovolts at sea level
-
Functional Terminal Type And Quantity
1 connector, plug input 1st function
-
Maximum Voltage Drop Per Function
1.0 volts ac 1st radio interference
-
Operating Current Rating Per Function In Amps
15.0 2nd radio interference
-
Nominal Thread Size
0.164 inches
-
Mounting Facility Screw Thread Series Designator
unc
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Operating Current Rating Per Function In Amps
15.0 1st radio interference
-
Body Height
4.000 inches nominal
-
Style Designator
rectangular terminal/terminals on two surfaces
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function